Analysis of the work dead zone of ultrasonic liquid level gauge

The blind zone of the ultrasonic liquid level gauge is like the blind zone of the human eye. When the object is close to the eye and the angle is fixed, it is not clear or invisible. This range is called the blind zone.

The working principle of the ultrasonic liquid level gauge is realized according to the transmission and reception of ultrasonic waves. The transmission speed of the ultrasonic wave in the air is fixed. The ultrasonic wave is emitted, and then the wave reflected from the liquid or object surface is received. The timing starts from the transmission and ends when the echo is received. The transmission time of the ultrasonic wave in the air is fixed. Because it is a round trip, the actual distance is half the distance. The depth of the tank or the height of the tank is fixed. The actual liquid level is the depth of the tank minus the distance measured by the ultrasonic liquid level gauge, which is the height of the liquid level or level. As a result, ultrasonic measurement of the liquid level or level is achieved.

The blind zone of the ultrasonic liquid level gauge is different according to the different measuring ranges. If the range is small, the blind zone is small, and if the range is large, the blind zone is large. But generally between 30cm-50cm. Therefore, when installing the ultrasonic liquid level gauge, the blind spot must be taken into account. On special occasions, the blind zone will be required to be very small. At this time, a small blind zone ultrasonic liquid level gauge can be considered. The blind zone is generally only 4-6cm. But its range is relatively small, only 0.6m. In many fields of liquid level measurement, due to space limitations and installation conditions, an ultrasonic liquid level gauge with a small dead zone is required.

The liquid level of the ultrasonic liquid level gauge enters the blind zone, and usually displays the position of the liquid level corresponding to the second echo. For example, if the blind zone is 0.3m and the distance from the liquid level to the transducer (or probe) surface is 0.2m, the level gauge will display the liquid level value corresponding to the spatial distance of 0.4m. Because the liquid surface reflects well when measuring the liquid level, the sound pulses emitted by the ultrasonic liquid level gauge will be reflected back to the liquid surface after reaching the surface of the transducer (or probe) after being reflected by the liquid surface, and It is reflected back to the transducer again and received. The echo at this time is the second echo. If the reflection conditions are good, multiple echoes (echoes from multiple round trips) may also be received.

30L Agriculture Drone

30L Agriculture Drone,Fertilizer Drone,Gfrp Agricultural Sprayer,Fold Sprayer Drone

Xuzhou Jitian Intelligent Equipment Co. Ltd , https://www.jitianequipment.com