The nominal operating frequency of the device is indicated on the outer casing of the quartz crystal, but that is only an approximation. In fact, the crystal has multiple resonant frequencies, even under ideal conditions.
Figure 1 shows an equivalent circuit of an ideal crystal in which there are only three circuit elements, a capacitor C1 in series and an inductor L1, and another capacitor C2 in parallel with the L1 C1 in series.
Figure 1: The equivalent circuit of an ideal quartz crystal
At a particular series resonant frequency, the input impedance Z is zero and L1 and C1 are in series resonance. Capacitor C2 has nothing to do with this.
However, at a particular parallel resonant frequency, the input impedance Z reaches infinity. This is the frequency at which the series combination of C2 and L1 C1 occurs in parallel resonance, exhibiting an inductive impedance. In order for the L1 C1 pair to be inductive in parallel resonance, the parallel resonance must occur at a higher frequency than the series resonance.
Therefore, the parallel resonant frequency can only be higher than the series resonant frequency, even if it is only a little higher. The parallel resonant frequency is never lower than the series resonant frequency. As for which resonance is more important to you, it depends on the application.
With uncomplicated mathematical operations, the impedance Z can be expressed as follows:
Figure 2: Impedance formula
Series resonant frequency: Fseries = 1/(2 * pi * sqrt(L1 C1))
Parallel resonant frequency: Fparallel = 1/(2 * pi * sqrt(L1 C1 C2 /(C1 + C2)))
Figure 3: Relative position of series and parallel resonance
Cross flow fans are mainly used for air conditioners, air curtain equipment, dryers, dry-type transformers, household appliances and equipment on grain combine harvesters
Service conditions of transformer cooling fan:
1. The ambient temperature shall be+75 ℃ ≥ - 40 ℃.
2. The industrial gas passing through the cooling fan is not allowed to have strong acid, strong alkali and various solutions.
3.Sand and dust and other sundries are not allowed to fall into the fan, so as to avoid fan burning and fan blade breakage.
Working principle
When GF series cooling fan is used for dry-type transformer, the fan is placed on both sides of the coil, and the cold air is directly blown into the high and low pressure cooling air passages of the dry-type transformer coil, which has obvious heat dissipation effect, ensuring the normal operation of the dry-type transformer and prolonging its service life. Fan start stop, transformer overtemperature alarm, overtemperature trip and other functions are provided by the temperature control device.
Maintenance and use
1. Before the fan is used, the insulation resistance shall be tested to be greater than 2 megohms. When the fan is hot or humid, the insulation resistance shall not be less than 0.5 megohms.
2. Before starting the fan, please check whether the appearance is intact, whether the connection is reliable, and whether the wind wheel rotates flexibly without blocking.
3. Clean the dust in the fan regularly to prevent affecting the air volume.