Signal Control Cable Copper Wire LSZH Braided Shield Wire

Model NO.: KVVP
Material Shape: Round Wire
Range of Application: LSOH
Certification: CE, CCC, RoHS
Brand: Sansen
Trademark: sansen-cable
Transport Package: as Requirement
Origin: China
HS Code: 8544492100
Model NO.: KVVP
Material Shape: Round Wire
Range of Application: LSOH
Certification: CE, CCC, RoHS
Brand: Sansen
Trademark: sansen-cable
Transport Package: as Requirement
Origin: China
HS Code: 8544492100

Signal Control Cable Copper Wire LSZH Braided Shield Wire

1,APPLICATION
Copper Conductor PVC Insulated PVC Sheathed Braid Screened Rigid Control Cable(KVVP) is mainly used for system connection wire of control,signal,protection or measuring for rated voltage up to and including 450/750V.

2,BASIC INFORMATION
Code Name 
KVVP
Rated Voltage (Uo/U)
450/750V
Cable Structure
CU/PVC Insulation/Braid Screened/PVC Sheathed
 
3,CONSTRUCTION
Conductor
Preferred Number of cores:
2,3,4,5,7,8,10,12,14,16,19,24,27,30,37,44,48,52,61
The conductors shall comply with the requirement given in IEC 60228 for class 1 or 2.
- class 1 for solid conductors;
- class 2 for stranded conductors.
Insulation
PVC(Polyvinyl Chloride) Type PVC/A according to IEC
Metallic Screened
Copper Wire Braid 
Sheathed
PVC(Polyvinyl Chloride) Type PVC/ST1 according to IEC
Other special application cable can be provided upon requests:
Fire-resistant,Flame-retardant,Low-halogen,Non-halogen,Low-fume,Low-smoke,as well as acid-alkali-proof,High temperature resistant,Termite and Rodent resistant,Water proof series and so on.

4,CABLE  STANDARDS
GB/T,JB/T,IEC,BS,DIN,ICEA up on request.
 
5,CHARACTERISTICS
Conductor temperature
Maximum conductor temperature in normal use: 70ºC
Installation temperature
Ambient temperature under installation shall not be below 0ºC
Max.temperature of conductor under short circuit
-(Max.Duration 5 sec.)
PVC Insulated:160ºC
Preferred Permissible bending radius
For non-armoured PVC insulated cable not less than: 6 times of cable diameter
KVVP model 450/750V PVC insulated control cable with PVC sheath and copper tape shielding

Core number*nominal cross section
mm2

Rated value of insulator thickness
mm

Shielded wire diameter
(mm)

Rated value of sheath thikness
(mm)

Diameter range
(mm)

Maximum DC resistance under temperature 20ºC
Ω/km
2*0.75 0.6 0.15 1.2 7.8-9.8 24.5
2*1.0 0.6 0.15 1.2 8.2-10.5 18.1
2*1.5 0.7 0.15 1.2 9.2-11.2 12.1
2*2.5 0.8 0.15 1.2 10.0-12.5 7.41
2*4 0.8 0.2 1.5 11.5-14.5 4.61
2*6 0.8 0.2 1.5 13.0-16.0 3.08
2*10 1 0.2 1.5 15.5-19.0 1.83
3*0.75 0.6 0.15 1.2 8.2-10.5 24.5
3*1.0 0.6 0.15 1.2 8.6-10.5 18.1
3*1.5 0.7 0.15 1.2 9.6-12.0 12.1
3*2.5 0.8 0.15 1.2 10.5-13.5 7.41
3*4 0.8 0.2 1.5 12.5-15.5 4.61
3*6 0.8 0.2 1.5 13.5-17.0 3.08
3*10 1 0.2 1.5 16.5-20.0 1.83
4*0.75 0.6 0.15 1.2 8.8-11.0 24.5
4*1.0 0.6 0.15 1.2 9.2-11.5 18.1
4*1.5 0.7 0.15 1.2 10.0-12.5 12.1
4*2.5 0.8 0.2 1.5 12.5-15.0 7.41
4*4 0.8 0.2 1.5 13.5-16.5 4.61
4*6 0.8 0.2 1.5 15.0-18.0 3.08
4*10 1 0.2 1.7 18.0-22.0 1.83
5*0.75 0.6 0.15 1.2 9.4-11.5 24.5
5*1.0 0.6 0.15 1.2 9.8-12.0 18.1
5*1.5 0.7 0.15 1.2 11.0-13.5 12.1
5*2.5 0.8 0.2 1.5 13.5-16.5 7.41
5*4 0.8 0.2 1.5 14.5-18.0 4.61
5*6 0.8 0.2 1.5 16.0-19.5 3.08
5*10 1 0.2 1.7 19.5-24.0 1.83
7*0.75 0.6 0.15 1.2 10.0-12.5 24.5
7*1.0 0.6 0.15 1.2 10.5-13.0 18.1
7*1.5 0.7 0.15 1.2 12.5-15.0 12.1
7*2.5 0.8 0.2 1.5 14.5-17.5 7.41
7*4 0.8 0.2 1.5 15.5-19.0 4.61
7*6 0.8 0.2 1.5 17.5-21.0 3.08
7*10 1 0.2 1.7 21.5-26.0 1.83
8*0.75 0.6 0.15 1.2 11.0-13.5 24.5
8*1.0 0.6 0.15 1.5 12.0-15.0 18.1
8*1.5 0.7 0.2 1.5 14.0-17.0 12.1
8*2.5 0.8 0.2 1.5 16.0-19.0 7.41
8*4 0.8 0.2 1.7 18.0-21.5 4.61
8*6 0.8 0.2 1.7 19.5-24.0 3.08
8*10 1 0.2 1.7 24.0-29.0 1.83
10*0.75 0.6 0.2 1.5 13.0-16.0 24.5
10*1.0 0.6 0.2 1.5 13.5-16.5 18.1
10*1.5 0.7 0.2 1.5 15.5-18.5 12.1
10*2.5 0.8 0.2 1.5 17.5-21.5 7.41
10*4 0.8 0.2 1.7 20.0-24.0 4.61
10*6 0.8 0.2 1.7 22.5-27.0 3.08
10*10 1 0.2 1.7 27.0-32.5 1.83
12*0.75 0.6 0.2 1.5 13.0-16.0 24.5
12*1.0 0.6 0.2 1.5 14.0-17.0 18.1
12*1.5 0.7 0.2 1.5 16.0-19.0 12.1
12*2.5 0.8 0.2 1.7 18.5-22.5 7.41
12*4 0.8 0.2 1.7 20.5-25.0 4.61
12*6 0.8 0.2 1.7 23.0-27.5 3.08
14*0.75 0.6 0.2 1.5 14.0-17.0 24.5
14*1.0 0.6 0.2 1.5 14.5-17.5 18.1
14*1.5 0.7 0.2 1.5 16.5-20.0 12.1
14*2.5 0.8 0.2 1.7 19.5-23.5 7.41
14*4 0.8 0.2 1.7 21.5-26.0 4.61
14*6 0.8 0.25 1.7 24.0-29.0 3.08
16*0.75 0.6 0.2 1.5 14.5-17.5 24.5
16*1.0 0.6 0.2 1.5 15.0-18.5 18.1
16*1.5 0.7 0.2 1.5 17.5-21.0 12.1
16*2.5 0.8 0.2 1.7 20.5-24.5 7.41
19*0.75 0.6 0.2 1.5 15.0-18.0 24.5
19*1.0 0.6 0.2 1.5 16.0-19.0 18.1
19*1.5 0.7 0.2 1.7 18.5-22.5 12.1
19*2.5 0.8 0.2 1.7 21.5-25.5 7.41
24*0.75 0.6 0.2 1.5 17.0-20.5 24.5
24*1.0 0.6 0.2 1.7 18.5-22.0 18.1
24*1.5 0.7 0.2 1.7 21.5-25.5 12.1
24*2.5 0.8 0.25 1.7 25.0-29.5 7.41
27*0.75 0.6 0.2 1.5 17.5-21.0 24.5
27*1.0 0.6 0.2 1.7 19.0-22.5 18.1
27*1.5 0.7 0.2 1.7 21.5-26.0 12.1
27*2.5 0.8 0.25 1.7 25.5-30.5 7.41
30*0.75 0.6 0.2 1.7 18.5-22.0 24.5
30*1.0 0.6 0.2 1.7 19.5-23.5 18.1
30*1.5 0.7 0.25 1.7 22.5-27.0 12.1
30*2.5 0.8 0.25 1.7 26.5-31.5 7.41
37*0.75 0.6 0.2 1.7 19.5-23.5 24.5
37*1.0 0.6 0.2 1.7 21.0-25.5 18.1
37*1.5 0.7 0.25 1.7 24.5-29.0 12.1
37*2.5 0.8 0.25 2 29.0-34.0 7.41
44*0.75 0.6 0.25 1.7 22.0-26.5 24.5
44*1.0 0.6 0.25 1.7 23.5-28.0 18.1
44*1.5 0.7 0.25 1.7 27.0-32.0 12.1
44*2.5 0.8 0.3 2 32.5-38.5 7.41
52*0.75 0.6 0.25 1.7 23.0-27.5 24.5
52*1.0 0.6 0.25 1.7 24.5-29.0 18.1
52*1.5 0.7 0.25 2 29.0-34.0 12.1
52*2.5 0.8 0.3 2 34.5-40.5 7.41
61*0.75 0.6 0.25 1.7 24.5-29.0 24.5
61*1.0 0.6 0.25 1.7 25.5-30.5 18.1
61*1.5 0.7 0.25 2 30.5-36.0 12.1
61*2.5 0.8
 
0.3 2.2 36.5-42.5 7.41

Signal Control Cable Copper Wire LSZH Braided Shield Wire
Signal Control Cable Copper Wire LSZH Braided Shield Wire
Signal Control Cable Copper Wire LSZH Braided Shield Wire


FAQ

Q1. What kind of products can your company supply?
 A: We specialize in supplying network cable, coaxial cable,power cable ,control cable , telephone cable, speaker cable and ect. 
 
Q2. What's your MOQ?
A: The MOQ of long meter cable is 50 km, or we can negociate. 
 
Q3. What's your delivery time? 
A: Our delivery time is about 15-20 days after comfriming the deposite, it is based on the quantity of the order.
 
Q4. What are your payment terms?
A: Normally, we accept T/T in advance, as for other payment term, we can negociate with you.
 
Q5. What's your trade term ? 
A: We can accept FOB, CIF, EXW term.  
 
Q6. What's your conventional packing ?
A: 100m/plastic or wooden drum, 305m/wooden drum or color box. However, we can produce according your demand.
 
Q7. Can your factory customize cables based on clients' samples or data sheet ? 
 A: Yes, we can. 

Q8. Can you offer me a free sample?
A: Yes, we do, that is a start of business I think, and you will only pay the cost of delivery, which we will return it to you when you put the order.

Jason Zhang | Sales Manager
Huzhou Sansen Cable Co.,Ltd.
 
Tel: + 86-572-8352155
 
Fax: +86-572-8182173
 
Mob: +86-15088322304
 
 
 
 
 
Gaolin Road, Xinshi Town, Deqing County, Zhejiang Province, China
 
http://www.sansen-cable.com
 
Signal Control Cable Copper Wire LSZH Braided Shield Wire

1,APPLICATION
Copper Conductor PVC Insulated PVC Sheathed Braid Screened Rigid Control Cable(KVVP) is mainly used for system connection wire of control,signal,protection or measuring for rated voltage up to and including 450/750V.

2,BASIC INFORMATION
Code Name 
KVVP
Rated Voltage (Uo/U)
450/750V
Cable Structure
CU/PVC Insulation/Braid Screened/PVC Sheathed
 
3,CONSTRUCTION
Conductor
Preferred Number of cores:
2,3,4,5,7,8,10,12,14,16,19,24,27,30,37,44,48,52,61
The conductors shall comply with the requirement given in IEC 60228 for class 1 or 2.
- class 1 for solid conductors;
- class 2 for stranded conductors.
Insulation
PVC(Polyvinyl Chloride) Type PVC/A according to IEC
Metallic Screened
Copper Wire Braid 
Sheathed
PVC(Polyvinyl Chloride) Type PVC/ST1 according to IEC
Other special application cable can be provided upon requests:
Fire-resistant,Flame-retardant,Low-halogen,Non-halogen,Low-fume,Low-smoke,as well as acid-alkali-proof,High temperature resistant,Termite and Rodent resistant,Water proof series and so on.

4,CABLE  STANDARDS
GB/T,JB/T,IEC,BS,DIN,ICEA up on request.
 
5,CHARACTERISTICS
Conductor temperature
Maximum conductor temperature in normal use: 70ºC
Installation temperature
Ambient temperature under installation shall not be below 0ºC
Max.temperature of conductor under short circuit
-(Max.Duration 5 sec.)
PVC Insulated:160ºC
Preferred Permissible bending radius
For non-armoured PVC insulated cable not less than: 6 times of cable diameter
KVVP model 450/750V PVC insulated control cable with PVC sheath and copper tape shielding

Core number*nominal cross section
mm2

Rated value of insulator thickness
mm

Shielded wire diameter
(mm)

Rated value of sheath thikness
(mm)

Diameter range
(mm)

Maximum DC resistance under temperature 20ºC
Ω/km
2*0.75 0.6 0.15 1.2 7.8-9.8 24.5
2*1.0 0.6 0.15 1.2 8.2-10.5 18.1
2*1.5 0.7 0.15 1.2 9.2-11.2 12.1
2*2.5 0.8 0.15 1.2 10.0-12.5 7.41
2*4 0.8 0.2 1.5 11.5-14.5 4.61
2*6 0.8 0.2 1.5 13.0-16.0 3.08
2*10 1 0.2 1.5 15.5-19.0 1.83
3*0.75 0.6 0.15 1.2 8.2-10.5 24.5
3*1.0 0.6 0.15 1.2 8.6-10.5 18.1
3*1.5 0.7 0.15 1.2 9.6-12.0 12.1
3*2.5 0.8 0.15 1.2 10.5-13.5 7.41
3*4 0.8 0.2 1.5 12.5-15.5 4.61
3*6 0.8 0.2 1.5 13.5-17.0 3.08
3*10 1 0.2 1.5 16.5-20.0 1.83
4*0.75 0.6 0.15 1.2 8.8-11.0 24.5
4*1.0 0.6 0.15 1.2 9.2-11.5 18.1
4*1.5 0.7 0.15 1.2 10.0-12.5 12.1
4*2.5 0.8 0.2 1.5 12.5-15.0 7.41
4*4 0.8 0.2 1.5 13.5-16.5 4.61
4*6 0.8 0.2 1.5 15.0-18.0 3.08
4*10 1 0.2 1.7 18.0-22.0 1.83
5*0.75 0.6 0.15 1.2 9.4-11.5 24.5
5*1.0 0.6 0.15 1.2 9.8-12.0 18.1
5*1.5 0.7 0.15 1.2 11.0-13.5 12.1
5*2.5 0.8 0.2 1.5 13.5-16.5 7.41
5*4 0.8 0.2 1.5 14.5-18.0 4.61
5*6 0.8 0.2 1.5 16.0-19.5 3.08
5*10 1 0.2 1.7 19.5-24.0 1.83
7*0.75 0.6 0.15 1.2 10.0-12.5 24.5
7*1.0 0.6 0.15 1.2 10.5-13.0 18.1
7*1.5 0.7 0.15 1.2 12.5-15.0 12.1
7*2.5 0.8 0.2 1.5 14.5-17.5 7.41
7*4 0.8 0.2 1.5 15.5-19.0 4.61
7*6 0.8 0.2 1.5 17.5-21.0 3.08
7*10 1 0.2 1.7 21.5-26.0 1.83
8*0.75 0.6 0.15 1.2 11.0-13.5 24.5
8*1.0 0.6 0.15 1.5 12.0-15.0 18.1
8*1.5 0.7 0.2 1.5 14.0-17.0 12.1
8*2.5 0.8 0.2 1.5 16.0-19.0 7.41
8*4 0.8 0.2 1.7 18.0-21.5 4.61
8*6 0.8 0.2 1.7 19.5-24.0 3.08
8*10 1 0.2 1.7 24.0-29.0 1.83
10*0.75 0.6 0.2 1.5 13.0-16.0 24.5
10*1.0 0.6 0.2 1.5 13.5-16.5 18.1
10*1.5 0.7 0.2 1.5 15.5-18.5 12.1
10*2.5 0.8 0.2 1.5 17.5-21.5 7.41
10*4 0.8 0.2 1.7 20.0-24.0 4.61
10*6 0.8 0.2 1.7 22.5-27.0 3.08
10*10 1 0.2 1.7 27.0-32.5 1.83
12*0.75 0.6 0.2 1.5 13.0-16.0 24.5
12*1.0 0.6 0.2 1.5 14.0-17.0 18.1
12*1.5 0.7 0.2 1.5 16.0-19.0 12.1
12*2.5 0.8 0.2 1.7 18.5-22.5 7.41
12*4 0.8 0.2 1.7 20.5-25.0 4.61
12*6 0.8 0.2 1.7 23.0-27.5 3.08
14*0.75 0.6 0.2 1.5 14.0-17.0 24.5
14*1.0 0.6 0.2 1.5 14.5-17.5 18.1
14*1.5 0.7 0.2 1.5 16.5-20.0 12.1
14*2.5 0.8 0.2 1.7 19.5-23.5 7.41
14*4 0.8 0.2 1.7 21.5-26.0 4.61
14*6 0.8 0.25 1.7 24.0-29.0 3.08
16*0.75 0.6 0.2 1.5 14.5-17.5 24.5
16*1.0 0.6 0.2 1.5 15.0-18.5 18.1
16*1.5 0.7 0.2 1.5 17.5-21.0 12.1
16*2.5 0.8 0.2 1.7 20.5-24.5 7.41
19*0.75 0.6 0.2 1.5 15.0-18.0 24.5
19*1.0 0.6 0.2 1.5 16.0-19.0 18.1
19*1.5 0.7 0.2 1.7 18.5-22.5 12.1
19*2.5 0.8 0.2 1.7 21.5-25.5 7.41
24*0.75 0.6 0.2 1.5 17.0-20.5 24.5
24*1.0 0.6 0.2 1.7 18.5-22.0 18.1
24*1.5 0.7 0.2 1.7 21.5-25.5 12.1
24*2.5 0.8 0.25 1.7 25.0-29.5 7.41
27*0.75 0.6 0.2 1.5 17.5-21.0 24.5
27*1.0 0.6 0.2 1.7 19.0-22.5 18.1
27*1.5 0.7 0.2 1.7 21.5-26.0 12.1
27*2.5 0.8 0.25 1.7 25.5-30.5 7.41
30*0.75 0.6 0.2 1.7 18.5-22.0 24.5
30*1.0 0.6 0.2 1.7 19.5-23.5 18.1
30*1.5 0.7 0.25 1.7 22.5-27.0 12.1
30*2.5 0.8 0.25 1.7 26.5-31.5 7.41
37*0.75 0.6 0.2 1.7 19.5-23.5 24.5
37*1.0 0.6 0.2 1.7 21.0-25.5 18.1
37*1.5 0.7 0.25 1.7 24.5-29.0 12.1
37*2.5 0.8 0.25 2 29.0-34.0 7.41
44*0.75 0.6 0.25 1.7 22.0-26.5 24.5
44*1.0 0.6 0.25 1.7 23.5-28.0 18.1
44*1.5 0.7 0.25 1.7 27.0-32.0 12.1
44*2.5 0.8 0.3 2 32.5-38.5 7.41
52*0.75 0.6 0.25 1.7 23.0-27.5 24.5
52*1.0 0.6 0.25 1.7 24.5-29.0 18.1
52*1.5 0.7 0.25 2 29.0-34.0 12.1
52*2.5 0.8 0.3 2 34.5-40.5 7.41
61*0.75 0.6 0.25 1.7 24.5-29.0 24.5
61*1.0 0.6 0.25 1.7 25.5-30.5 18.1
61*1.5 0.7 0.25 2 30.5-36.0 12.1
61*2.5 0.8
 
0.3 2.2 36.5-42.5 7.41

Signal Control Cable Copper Wire LSZH Braided Shield Wire
Signal Control Cable Copper Wire LSZH Braided Shield Wire
Signal Control Cable Copper Wire LSZH Braided Shield Wire


FAQ

Q1. What kind of products can your company supply?
 A: We specialize in supplying network cable, coaxial cable,power cable ,control cable , telephone cable, speaker cable and ect. 
 
Q2. What's your MOQ?
A: The MOQ of long meter cable is 50 km, or we can negociate. 
 
Q3. What's your delivery time? 
A: Our delivery time is about 15-20 days after comfriming the deposite, it is based on the quantity of the order.
 
Q4. What are your payment terms?
A: Normally, we accept T/T in advance, as for other payment term, we can negociate with you.
 
Q5. What's your trade term ? 
A: We can accept FOB, CIF, EXW term.  
 
Q6. What's your conventional packing ?
A: 100m/plastic or wooden drum, 305m/wooden drum or color box. However, we can produce according your demand.
 
Q7. Can your factory customize cables based on clients' samples or data sheet ? 
 A: Yes, we can. 

Q8. Can you offer me a free sample?
A: Yes, we do, that is a start of business I think, and you will only pay the cost of delivery, which we will return it to you when you put the order.

Jason Zhang | Sales Manager
Huzhou Sansen Cable Co.,Ltd.
 
Tel: + 86-572-8352155
 
Fax: +86-572-8182173
 
Mob: +86-15088322304
 
 
 
 
 
Gaolin Road, Xinshi Town, Deqing County, Zhejiang Province, China
 
http://www.sansen-cable.com
 

Fishing Power Bank Pack

By capacity, 400 Wh to 1,000 Wh segment is expected to dominate the global portable power station market.

The 400 Wh to 1,000 Wh segment is expected to be the largest, by capacity, during the forecast period. The growth of this segment is owing to the rising demand for additional power capacity and charging electronic appliances with high power requirements across North America, Europe, and Asia Pacific regions.

By sales channel, online sales segment is expected to dominate the global portable power station market.

The portable power station market in North America for the online sales segment holds the largest market share. The manufacturers need not have to stock more products while selling online, also due to the current COVID-19 pandemic, the demand for online sales channels has significantly increased. Also, the high profit margins by selling directly to customers is expected to increase demand for this segment.

By region, North America is expected to lead the portable power station market, in terms of value.

North America is the largest market for portable power stations globally, followed by Asia Pacific and Europe. The region is also projected to be the fastest-growing market during the forecast period owing to the increasing use of smart electronics and the rising number of incidences of power outages in countries such as the US, Canada, and Mexico.


Carp Fishing Power Pack,Best Power Pack For Fishing,Carp Fishing Battery Pack,Fishing Power Bank Pack

Shenzhen Zhifu New Energy Co., Ltd. , https://www.sunbeambattery.com