Beijing's first standard night lighting standard for soliciting opinions

In the future, isolation protection measures should be taken when the surface temperature of the lighting equipment accessible to personnel is higher than 60 °C.

The reporter learned from the Beijing Municipal Bureau of Quality and Technical Supervision this morning that the city’s first mandatory local standard for night lighting technology requirements, “Night Scene Lighting Safety Regulations”, is open for public comment. Some of the content in the specification refers to the above information.

It is reported that all night lighting fixtures installed on ancient buildings must have fire prevention measures in the future. At the same time, night lighting should not interfere with traffic signals.

The standard also requires that all live parts of the lighting equipment shall be protected against electric shock by insulation, obstruction or external protection; the lamps that are accessible to the human body on the protective fence (wall) such as the viewing platform, bridges shall be Class III lamps (protection against electric shock) The power supply voltage is a safety extra low voltage).

In particular, it should be noted that isolation protection measures should be taken when the surface temperature of the lighting equipment accessible to personnel is higher than 60 °C; floor-standing lamps installed in dense places such as sidewalks without fence protection, the installation height should be 2.5 meters from the ground. the above.

The standard specifically proposes that the luminaires installed on the ancient buildings should adopt fire prevention measures and have fireproof signs; night lighting should not interfere with the normal use of traffic signals and communication equipment; dynamic lighting should not be used on overpasses and overpass bridges; Decorative lights with fast color changes and multiple light sources should be used in large quantities and continuously.

The standard also stipulates that the luminaires should be reliably fixed. The luminaires used in the vibrating place should have anti-shock measures. The luminaires installed at high altitude should have anti-wind pressure measures. The brackets and parts required for the installation of the luminaires should be treated with anti-corrosion treatment. In addition, the neon tube should be fixed by a special insulating bracket, and it is firm and reliable, and its distance from the surface of the building should be no less than 20mm.

It is reported that the standard will be applied to lighting fixtures for buildings, bridges, gardens, places of interest, roads, parking areas, green spaces, sculptures, outdoor activities, etc.

News attention to the square lights will bid farewell to "streaking"

For the content of "Isolation protection measures should be taken when the surface temperature of the lighting equipment accessible to personnel is higher than 60 °C", the relevant quality supervision experts told the reporter that this is mainly for the installation of exposed ground lights and other facilities in the square and other places.

The newspaper and other media have previously reported that many cities, including the city, had urchins touching the square lights, causing burns because of the high temperature of the ground lights without any “blocking” facilities, making them lack self-protection. A child of consciousness is injured.

Experts pointed out that after the implementation of the new standard, the exposed ground lamp will be extinct.