Model NO.: JKWF16
Electrolyte: Air Medium
Usage: Low Frequency Coupling
Tuning: Polystyrene Capacitor
Filter: Aluminum Electrolytic Capacitor
Material: Anti Fire Plastic Case
Power Factor Correction PCB: Relay Control Signal
Power Supply: Power Transformer 230V~400V
Power Control: Relay
Power Sensor: CT Type
Power Capacity: 0~9999
Power Factor Correction Function: Correct Measure Reactive Current
Display: LED/LCD
Over Voltage Setting: 230V~500V
Control Step: 1~16 Step
Trademark: OEM
Transport Package: 12PC/Per CTN 42*42*35cm
Specification: CE ROHS
Origin: Yueqing Zhejiang
HS Code: 8537909000
dynamic output Split Phase Compensate Power Factor Correction 16step Jkwf16220v  auto setNormally: A B C Three phaseÂ
JKWF16 type ,if three phase unbalance ,it will compesate one of phase (For example only B phase )
1.LED show three phase voltage current ,active power ,reactive power ,current power ,power factor and electric net frequency and control dataÂ
(taking this power factor capacitor bank which can save current meter ,voltage meter and universal switchover )
2.strong anti interference ability , when 2000v power  input ,the products is  no power off ,no lose data ,stable workingÂ
3.user can setting the data according yourself demanding ,when power is off ,it would not lose before dataÂ
4.over voltage under voltage and lose phase protection functionÂ
5.compensate way : split compensate ,three phase compensate with split phase Â
6.output way :static ,dynamicÂ
Item | Name |  dynamic output Split Phase Compensate Power Factor Correction 16step Jkwf16220v  auto set |
1 | LED/LCD Display will show  a.three-phase voltage,current, active power, reactive b.power factor and power network frequency, control parameter |
|
2 | Strong anti-interference ability can resist 2kv impulse test ,keep data | |
3 | You can revise control data sheet ,it will save data no power | |
4 | Auto analysis phase function | |
5 | Current get signal resistor less than 0.05Ω | |
6 | Over voltage ,under voltage lack phase protection function | |
7 | Input way: static ,Dynamic ,compound | |
8 | Rated voltage | AC 220V±10%  AC 380V±10% |
9 |  Rated current | AC 0-5A |
10 | Rated frequency | 50Hz±5% |
11 | Sensitivity | 100mA |
12 | COS φ Preset |  0.80-0.99; step length 0.01; Factory preset 0.98 input and cutoff time |
13 | Input Delay | dynamic state 100ms-30S; Static state 1-250S;Factory preset dynamic state 5S; static state 30S. |
14 | Over-voltage protection | 230-260V; step length 1V; Return difference 6V  reset 240V, |
15 | Under-voltage protection | 180V;return difference 6V |
16 | Auto Discriminating Phase | ON/OFF; factory preset ON(Auto discriminating ON) |
17 | Reactive threshold | OFF-4-100kvar; factory preset OFF (reactive threshold inefficiency) |
18 | CT variation | 50/5A-3000/5A; step length 1; factory preset 500/5A |
19 | Capacitance capacity | 0-99kvar factor preset of each branch 10kvar |
20 | Contact capacity | dynamic state output of each branch DC12V×50mA Static state output of each branch 380V×7A/200V×5A |
21 | size | 113*113Â Â Â 138*138 |
dynamic output Split Phase Compensate Power Factor Correction 16step Jkwf16220v  auto set advantageÂ
1.20 years global leading profession manufacture of energy meter Â
2, the precision of measurement
The current identification: the controller can judge the sampling current polarity and automatic conversion.
3, the display of choice
4, parameter setting function
5, protection function
6. control strategy, capacitors
7. output circuit designÂ
8.Fast delivery : you will get the order when you need itÂ
9.OEM is warmly welcomeÂ
10.Convenient : 45 minutes to wenzhou airportÂ
Â
dynamic output Split Phase Compensate Power Factor Correction 16step Jkwf16220v  auto set functionÂ
Control signal: comprehensive control by using the power factor and reactive current of two physical quantities;
1.Step :step number selected by the user;
2.Data storage: after the loss of electricity parameter settings will not be lost, data save permanently;
3.Adaptability: automatically adapt to the distribution system of different parameters of the controller, does not need to provide the transformation ratio of current transformer and capacitor compensation capacity;
4.Overvoltage protection: the voltage is higher than the set value quickly over voltage, gradual resection capacitors have been put;
5.Strong anti-interference:Â
unique design, crash, indiscriminately, indiscriminate cutting phenomenon can not occur in operation;
Switching shocks: can prevent the small current load and over voltage critical values appear repeated switching;
6.High sensitivity: compensator can work normally in the input signal when the current is 0.10A;
7.Display error: input signal power of current 0.10A to 5A changes due tonumerical error measurement showed minimal;
8.The current identification: the controller can judge the sampling current polarity and automatic conversion.
Â
dynamic output Split Phase Compensate Power Factor Correction 16step Jkwf16220v  auto set Payment termsÂ
1. 30% T/T advance , the balance against to the copy B/Lor LC at sighÂ
2. The other specific issues can negorate.
3. Pls confirm the details with us before do the prepayment.
Â
dynamic output Split Phase Compensate Power Factor Correction 16step Jkwf16220v  auto set  Packing informationÂ
1. Inside foam package ,outside strong paper packageÂ
2. 12pcs/per CTNÂ
3. G/N.W: 12/11kg
4. We can packing as your required,good looking designÂ
Â
Why choose dynamic output Split Phase Compensate Power Factor Correction 16step Jkwf16220v  auto set
1).ISO9001,SGS,Gold golden supplierÂ
2) Monthly Production Capacity -- 100000 PcsÂ
3)All goods examined before delivery by 10 QC staffÂ
4)Prompt Reply Within 12 HoursÂ
5)8000 square meters work environmentÂ
Triac Dimmable Constant Current LED Driver
Triac Dimmable Constant Current LED Driver,LED Driver Circuit,LED Controler,LED Transformer
LED Power Supply Co., Ltd. , http://www.nbleddriver.com